MEMOLUB® HPS Lubricator - Hazardous Locations
The MEMOLUB® EX is the same self-contained, battery powered lubricator as the MEMOLUB® HPS model with a modified enclosure rated for limited hazardous locations.
Click here for technical data sheet
| Specifications: | |||||||
| EX (Hazardous Locations) | |||||||
| Rating | EEX nC II T6 - T85°C - IP66 | ||||||
| Media | Grease ( to NLGI #2) or Oil | ||||||
| Lubricant Cartridge Capacity | 120cc , 240cc (Replaceable) | ||||||
| Delivery Method | Metered Quantity | ||||||
| Lubricant Flow Rate | 52 Adjustable Volume Output Settings (0.63cc / Stroke - standard) | ||||||
| Strokes per day | 0.5, 1, 1.5, 2, 4, 12 or 24 | ||||||
| Operating Pressure | 350psi (25 bar) | ||||||
| Operation | Electro-Mechanical- Positive Replacement Pump | ||||||
| Feed Type | Single-Point or Multi-Point | ||||||
| Temperature Range ** | 5°F to 141°F (-15°C to 50°C) | ||||||
| Power Supply | 4.5VDC Battery Pack (Replaceable) | ||||||
| External On/Off Control | No | ||||||
| Mounting Thread Size | 1/4" NPT(M) -(1/8" NPT(M) available) | ||||||
| Multi-Point Compatible | Yes | ||||||
| Splitter Block Compatible * | Yes | ||||||
| Remote Installation (single-point) | Up to 40 feet (12 meters) | ||||||
| * Splitter Blocks cannot be used with oil, and are limited to 7 lubricant output settings. | |||||||
| ** Lower temperatures can be achieved by using a lowtemp grease an cold-weather battery packs. | |||||||