MEMOLUB® HPS Lubricator

The MEMOLUB® HPS (High Pressure System) is a versatile, technologically advanced, self-contained automatic lubricator. Its unique patented design offers capabilities not found in other industrial single-point automatic lubricators currently in use.
The positive displacement pump of the MEMOLUB® HPS ejects lubricant at an impressive 350psi, from the first stroke to the last. When you turn the MEMOLUB® HPS on, it begins lubricating without delay. The high lubricant ejection pressure opens new areas of applications. The ability to place the MEMOLUB® HPS remotely up to 40 feet (12 meters) from the lubrication point and to lubricate up to 12 lube points with a single lubricator makes the MEMOLUB® HPS one of the most versatile self-contained lubricators available today.
The MEMOLUB® HPS is available in three sizes: 
- STANDARD: Model 120
Cartridge capacity 120cc, approximately 1/4 pound (113g) - MEGA: Model 240
Cartridge capacity 240cc, approximately 1/2 pound (227g) - GIGA: Model 480
Cartridge capacity 480cc, approximately 1 pound (454g)
All MEMOLUB HPS models use the same motor base assembly, making it easy to convert from one model to another with the purchase of a low-cost Housing Adaptor Kit.
| Specifications: | |
| HPS (High Pressure System) | |
| Media | Grease ( to NLGI #2) or Oil |
| Lubricant Cartridge Capacity | 120cc , 240cc, 480cc (Replaceable) |
| Delivery Method | Metered Quantity |
| Operation | Electro-Mechanical- Positive Displacement Pump |
| Lubricant Flow Rate | 52 Adjustable Volume Output Settings (0.63cc / Stroke - standard) |
| Strokes per day | 0.5, 1, 1.5, 2, 4, 12, 24 |
| Operating Pressure | 350psi (25 bar) |
| Feed Type | Single-Point or Multi-Point |
| Temperature Range ** | 5°F to 122°F (-15°C to 50°C) |
| Power Supply | 4.5VDC Battery Pack (Replacable) |
| External On/Off Control | No |
| Mounting Thread Size | 1/4" NPT(M) - (1/8" NPT(M) available) |
| Multi-Point Compatible | Yes |
| Splitter Block Compatible * | Yes |
| Remote Installation (single-point) | Up to 40 feet (12 meters) |
| * Splitter Blocks cannot be used with oil, and are limited to 7 lubricant output settings. | |
** Lower temperatures can be achieved by using a lowtemp grease an cold-weather battery packs.
| |
Replacement Kits
Hazardous Locations